EPM 6010 | Building Automation Power Meter

EPM 6010 | Building Automation Power Meter

The Multilin EPM 6010 is an industry leading revenue grade power meter with native BACnet/IP communications. This meter is designed to integrate seamlessly into existing and new building management systems using the popular BACnet protocol. The meter allows users to gather data on voltage, current, power and energy usage throughout a facility. This meter is available in a transducer configuration (EPM 6010T) that comes without a display and has a DIN rail mount. It’s ideal for use in retrofit applications and where budgets are a large consideration.

The Multilin EPM 6010 is an industry leading revenue grade power meter with native BACnet/IP communications. This meter is designed to integrate seamlessly into existing and new building management systems using the popular BACnet protocol. The meter allows users to gather data on voltage, current, power and energy usage throughout a facility. This meter is available in a transducer configuration (EPM 6010T) that comes without a display and has a DIN rail mount. It's ideal for use in retrofit applications and where budgets are a large consideration.

KEY BENEFITS

  • Rapid integration into BACnet management systems
  • High accuracy multifunction power meter,0.2% class revenue certifiable energy and demand metering
  • Ultra compact and easy to install,fits both ANSI and DIN cutouts
  • EnerVista™ software makes metered data and power quality status easily accessible
  • User programmable for different system voltages and current measurements
  • Standard Modbus™ TCP communications
  • Easy to read, large 3 line. 56" bright LED display for better visibility and longer life

APPLICATIONS

  • LED projects
  • Smart buildings
  • Commercial energy management
  • HVAC efficiency monitoringBuilding management systems


FEATURES


Communications

  • BACnet/IP100BaseT Ethernet protocol
  • 40 pre-defined BACnet objects facilitate rapid integration
  • Embedded web-server,allows BACnet/IPinterface to be remotely configured and BACnet object scan be remotely view edover the internet with a web browser
  • Standard Modbus TCP communications can be used to poll the EPM 6010 while BACnet/ IPinterface is being used

Measuring and Metering

  • High accuracy multifunction power meter, 0.2% class revenue certifiable energy and demand metering
  • Samples at 400 + times per cycle and has 24 bit A/D conversion to measure accurately and reliably
  • Meets ANSIC 12.20(0.2%) and IEC687 (0.2%) accuracy classes
  • Total harmonic distortion (%THD)
  • Load percentage graphical bar for instant load visualization
  • True RMS multifunction measurements including voltage, current, power, frequency and energy