MEGGER CI | Cable Identification

MEGGER CI  | Cable Identification

Reliable cable selection for de-energised and energised (live) cables

  • Identifies a de-energised primary cable safely
  • Identifies live secondary cables up to 240 V AC
  • Avoids false positives
  • Easy and safe to operate

The CI cable identifier will safely identify a dead (or de-energised) primary cable within a group of energised or de-energised cables. It can also indentify live secondary cables, including neutrals, up to 240 V AC (440 optional).

This absolutly safe identification method done by the CI is based on polarity and signal magnitude of the DC pulse (up to 100 A) coming from the transmitter, which is picked up by the receiver and a clip-on probe. The transmitter can operate on 120 V AC or via its internal battery that gives you up to 50 hours run time. The entire CI system functions without user adjustments and will never provide a false positive identification.

The standard combination kit, for high and low voltage cables, includes a 6-inch flexible clip-on probe and two touch sensors for all the applications where a clip-on cannot be used.

Transmitter for identification on de-energised cables CI TX-1

Pulse voltage55 VDC
Pulse currentmax. 100 A
Pulse sequence30 min-1
Pulse width72 ms
Power supply100 … 240 VAC; 50 / 60 Hz;
12 VDC rechargeable battery
Operating time4 h (Li-ion rech. battery)
Charging time6 h
Weight1,6 kg
Dimensions (W x H x D)201 x 120 x 80 mm
Protection classIP 54
Operating temperature range- 10 °C … + 60 °C
Storage temperature range- 10 °C … + 60 °C
Relative humidity93 % at 30 °C (non-condensing)


Universal-receiver CI RX

SensorFlex coupler
dia. approx. 150 or 250 mm
Amplifier setting3 … 24 dB in 10 steps
Power supply2 x 1,5 V AA batteries
Operating time> 50 h
Weight0,4 kg
Dimensions (W x H x D)150 x 65 x 35 mm
Protection classIP 54
Operating temperature range- 10 °C … + 60 °C
Storage temperature range- 10 °C … + 60 °C
Relative humidity93 % at 30 °C (non-condensing)


Transmitter for identification on energised cables LCI TX-1

Operating voltage100 … 240 VAC; 50 / 60 Hz
Pulse current80 A
Pulse sequence30 min-1
Pulse width1,5 ms
Weight0,5 kg
Dimensions (W x H x D)151 x 101 x 60 mm
Protection classIP 54
Operating temperature range- 10 °C … + 60 °C
Storage temperature range- 10 °C … + 60 °C
Relative humidity93 % at 30 °C (non-condensing)


Transmitter for phase to phase identification on energised cables LCI TX 440

Operating voltage240 … 440 VAC; 50 / 60 Hz
Pulse current80 A
Pulse sequence30 min-1
Pulse width1,5 ms
Weight0,5 kg
Dimensions (W x H x D)151 x 101 x 60 mm
Protection classIP 54
Operating temperature range- 10 °C … + 60 °C
Storage temperature range- 10 °C … + 60 °C
Relative humidity93 % at 30 °C (non-condensing)